ABB IRC5 Operating Manual page 219

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

40076, Reference error
Description
arg not label reference.
Recommended actions
The specified name identifies an object other than a label. Check
if the desired label is hidden by some other object with the same
name.
40077, Reference error
Description
arg not optional parameter reference in conditional argument
value.
Recommended actions
The specified name identifies an object other than an optional
parameter. Change the name to refer to an optional parameter.
40078, Reference error
Description
arg not optional parameter reference.
Recommended actions
The specified name identifies an object other than an optional
parameter. Change the name to refer to an optional parameter.
40079, Reference error
Description
Task arg: arg is not a procedure reference.
Recommended actions
The specified name identifies an object other than a procedure.
Check if the desired procedure is hidden by some other object
with the same name.
40080, Reference error
Description
arg not required parameter reference.
Recommended actions
The specified name identifies an object other than a required
parameter. Change the name to refer to a required parameter.
40081, Reference error
Description
arg not trap reference.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
Recommended actions
The specified name identifies an object other than a trap. Check
if the desired trap is hidden by some other object with the same
name.
40082, Reference error
Description
arg not type name.
Recommended actions
The specified name identifies an object other than a type. Check
if the desired type is hidden by some other object with the same
name.
40083, Type error
Description
arg not value type.
Recommended actions
Only variables that lack initial value, and 'VAR' mode parameters
may be of semi-value or non-value type.
40086, Reference error
Description
Reference to unknown label arg.
Recommended actions
The routine contains no label (or other object) with the specified
name.
40087, Reference error
Description
Reference to unknown optional parameter arg.
Recommended actions
The called routine contains no optional parameter (or other
object) with the specified name.
40089, Reference error
Description
Reference to unknown record component arg.
Recommended actions
The record type contains no record component with the
specified name.
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
Continues on next page
5.6 4 xxxx
Continued
219

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents