ABB IRC5 Operating Manual page 534

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

5 Troubleshooting by event log
5.10 11 xxxx
Continued
112529, WDM Major Infraction
Description
A major arg infraction has occurred in seam arg.
Measured value: arg
Maximum limit: arg
Minimum limit: arg
112530, WDM Error
Description
An unspecified error has occurred in the Weld Data Monitor for
task arg
Recommended actions
Please contact your ABB representative.
112531, WDM Trigger Ready
Description
Weld Data Monitor is ready to sample data for task arg
112532, WDM Trigger Subscriptions Failed
Description
Weld Data Monitor trigger subscriptions failed for task arg
Consequences
Weld Data Monitor will be inoperable.
112533, WDM Trigger IO Setup Failed
Description
Weld Data Monitor trigger IO connections failed for task arg
Consequences
Weld Data Monitor will be inoperable.
112534, WDM Weave Frequency Error
Description
Weave frequency is too fast for arg in task arg.
Consequences
WDM will reduce sampling rate to a fraction of the weave
frequency.
112535, WDM Weave Frequency Error
Description
Weave frequency is too fast for arg in task arg.
Consequences
No monitoring will occur.
Continues on next page
534
Recommended actions
Please reduce weave frequency to enable Weld Data Monitoring.
112536, WDM Weave Change Error
Description
The weave parameters have changed since learning of seam
arg in task arg.
Consequences
No monitoring will occur.
Recommended actions
Please remove the stored signature and relearn with new
parameters. Or, reinstate old parameters.
112537, WDM Speed Change Error
Description
The weld travel speed has changed since learning of seam arg
in task arg.
Consequences
No monitoring will occur.
Recommended actions
Please remove the stored signature and relearn with new
parameters. Or, reinstate old parameters.
112538, WDM Seam Length Changed
Description
The weld seam length has changed since learning of seam arg
in task arg.
Consequences
No monitoring will occur.
Recommended actions
If the targets defining the seam were intentionally modified,
please remove the stored signature and relearn with the new
targets.
112539, WDM Sample Frequency Error
Description
Sampling frequency is too fast for arg in task arg.
Consequences
WDM will reduce sampling rate to a fraction of the requested
frequency.
© Copyright 2005-2018 ABB. All rights reserved.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA

Hide quick links:

Advertisement

Table of Contents
loading