This device command has been rejected.
Recommended actions
Correct the service identifier for the device command.
71339, Device command without reference to I/O
device
Description
The I/O configuration is invalid.
The device command arg has no reference to an I/O device.
The device command must have a reference to an existing I/O
device.
Consequences
This device command has been rejected, and no functions
depending on it will work.
Recommended actions
Define an I/O device reference for the device command.
71340, Device command with reference to
non-existing I/O device
Description
The I/O configuration is invalid.
The device command arg has a reference to an invalid/unknown
I/O device arg.
The device command must have a reference to an existing I/O
device.
Consequences
This device command has been rejected, and no functions
depending on it will work.
Recommended actions
Correct the I/O device for the device command.
71344, Device map undefined
Description
The I/O configuration for I/O signal arg is invalid.
Device map is undefined or empty.
A Device map must be specified for all physical I/O signals (i.e.
signals connected to an I/O device).
This I/O signal has been rejected.
Recommended actions
Define a device map for the I/O signal.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
71346, Device map out of range
Description
The I/O configuration for I/O signal arg is invalid.
The device map arg is invalid since bit arg is out of range.
All bits in the device map must be in the range [0, arg].
This I/O signal has been rejected.
Recommended actions
Correct the device map.
71347, Device map with overlapping segments
Description
The I/O configuration for I/O signal arg is invalid.
The device map arg contains segments (e.g. bit arg) that overlap
each other.
This I/O signal has been rejected.
Recommended actions
Correct the device map.
71348, Device map with unexpected character
Description
The I/O configuration for I/O signal arg is invalid.
Found unexpected end or character at position arg in the device
map: arg.
This I/O signal has been rejected.
Recommended actions
Correct the device map so that is comply with the following
syntax: {bit} = ([0-9]+) {range} = ([0-9]+[-][0-9]+) {segment} =
({bit} | {range}) {device map} = ({segment}[,])*{segment}
Examples of valid device maps: "1" "0-7, 15-8" "1,4-3,7"
71349, Invalid signal size
Description
The I/O configuration for I/O signal arg is invalid.
There is a mismatch between the signal type and the size of
the signal.
The signal size arg is given by the device map: arg.
This I/O signal has been rejected.
Recommended actions
Correct either the signal type or the device map so that the
following rules are fulfilled: The size of digital I/O signals must
be exactly one bit. The size of analog and group I/O signals
must be between 1 and 32 bits.