71492, PROFINET diagnostic data reported
Description
The I/O device arg has reported diagnostic data on slot arg.
arg
71493, PROFINET I/O device auto configured
Description
A new I/O device has been found in the PROFINET configuration
file. This I/O device has been auto configured in the controller
with the following parameters:
Device name: arg.
Input bytes: arg.
Output bytes: arg.
Recommended actions
Edit or delete the configuration. Restart the controller to activate
the I/O device configuration.
71494, PROFINET option key missing
Description
The option key needed to run the arg network on the controller
was not detected.
Consequences
No communication on arg network is possible.
Probable causes
An attempt may have been made to add the PROFINET
functionality, without installing the option correctly.
Recommended actions
Configure a new system with the PROFINET option, and install
that system. If PROFINET is not required, configure a new
system without this option, and install that system.
71495, PROFINET controller option key missing
Description
The option key needed to run the arg network as a PROFINET
controller on the controller was not detected. The I/O device
arg is not defined as an internal PROFINET device.
Consequences
No communication with the I/O device arg is possible.
Probable causes
The installed option key for the arg network only supports one
internal PROFINET device.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
Recommended actions
Configure a new system with the PROFINET controller/device
option or remove the I/O device arg from the I/O configuration.
71498, PROFINET network configuration changed
Description
I/O configuration for the network arg have been changed by an
external configuration tool or a connecting controller.
The following values have been changed:
Station name: arg.
71499, I/O signals in cross connection has
overlapping device map
Description
The I/O configuration of cross connection arg is invalid.
The resultant I/O signal arg has an overlapping device map with
the inverted actor I/O signal arg.
Using I/O signals with overlapping device map in a cross
connection can cause infinity signal setting loops.
Consequences
The cross connection has been rejected, and no functions
depending on it will work.
Recommended actions
Correct the device map or define one of the I/O signals as
simulated.
71500, EtherNet/IP connection failure
Description
Not able to connect to the adapter arg.
arg
Consequences
No communication with the adapter is possible.
71501, PROFINET configuration file error
Description
The PROFINET configuration file arg was not valid. Internal
error code arg.
Consequences
No communication on arg network is possible.
Probable causes
The PROFINET configuration file may be corrupt or have been
created with an incompatible file format.
Recommended actions
Generate a new PROFINET configuration file.