ABB IRC5 Operating Manual page 454

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

5 Troubleshooting by event log
5.10 11 xxxx
Continued
You might want to handle errno arg in your error handler
110042, Process Supervision Phase
START_POST2
Description
Task: arg
Supervision failed for process phase START_POST2.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110100, Fatal process error
Description
Task: arg
A fatal process error has been reported. Check previous error
messages for more information about the reason of the error.
Recommended actions
A restart of the system or move of program pointer is highly
recommended.
110101, Invalid weave shape
Description
Task: arg
The weave shape used is invalid:
[No shape = 0, Zig-zag shape = 1, V-shape = 2, Triangular shape
= 3]
Recommended actions
Correct the shape component.
110102, Invalid weave length
Description
Task: arg
The weave length used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component length.
110103, Invalid weave cycle time
Description
Task: arg
Continues on next page
454
The weave cycle time used is invalid:
(0 - 100) [s]
Recommended actions
Correct the component cycle_time.
110104, Invalid weave width
Description
Task: arg
The weave width used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component width.
110105, Invalid weave height
Description
Task: arg
The weave height used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component height
110106, Invalid weave dwell left
Description
Task: arg
The weave dwell_left used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component dwell_left
110107, Invalid weave dwell center
Description
Task: arg
The weave dwell_center used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component dwell_center
110108, Invalid weave dwell right
Description
Task: arg
The weave dwell_right used is invalid:
(0 - 1) [m]
© Copyright 2005-2018 ABB. All rights reserved.