ABB IRC5 Operating Manual page 462

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

5 Troubleshooting by event log
5.10 11 xxxx
Continued
110229, Application error
Description
Task arg:
Error from arg . The data type definitions exceed the maximum
data storage size.
arg
Recommended actions
Check the data size.
110230, Application error
Description
Task arg:
Not possible to execute instruction in motors off state for servo
tool arg .
Recommended actions
Retry after setting motors on.
110231, Application process time warning
Description
Task arg:
arg. Max process time exceeded, waiting for process complete.
Time: arg s.
Recommended actions
Check the application code for any delays preventing the
process to finish.
110300, Parameter error
Description
Task: arg
The max string length of the parameter arg is 5 characters.
Current used name is arg.
See specification in arg.
arg
Recommended actions
Check the length of the string data value.
110302, Parameter error
Description
Task: arg
The specified signal arg in the instruction arg has no reference.
arg
Probable causes
The signal reference is not valid, no AliasIO has been done or
the signal is write protected in the EIO configuration..
Continues on next page
462
Recommended actions
Check the EIO configuration.
110303, Parameter error
Description
Task: arg
The optional signals \arg and \arg must be used together.
See specification in arg.
arg
Recommended actions
Check the program.
110304, Parameter error
Description
Task: arg
The parameter arg of the instruction arg is not an array.
arg
Recommended actions
Check the data definition.
110305, Parameter error
Description
Task: arg
The dimension of the data array arg is to big.
See specification in arg.
arg
Recommended actions
Check the data declaration.
110306, Parameter error
Description
Task: arg
The array arg of the instruction arg is not right defined.
arg
Recommended actions
Check the data against the specification.
110307, Parameter error
Description
Task: arg
The event time array element arg.arg is less than 0.
See specification in arg.
arg
© Copyright 2005-2018 ABB. All rights reserved.