ABB IRC5 Operating Manual page 295

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

Recommended actions
Either run Trigg without \Time optional argument, or use
TriggRampAO with optional argument \Time to specify that the
RampLength is seconds instead of distance.
41673, Index Out Of Bounds
Description
Task: arg.
Index for cfg instance was out of bounds.
Program ref: arg.
Recommended actions
Check and change the RAPID program.
Recovery: arg.
41674, Value Out Of Bounds
Description
Task: arg.
Parameter arg is not in the range of 0 to 100.
Program ref: arg.
Recommended actions
Check and change the RAPID program.
Recovery: arg.
41675, Not Integer
Description
Task: arg.
Parameter arg is not an integer.
Program ref: arg.
Recommended actions
Check the RAPID program, or use ERROR handler.
Recovery: arg.
41676, Device access error
Description
Task:arg Unable to open File or Serial channel, 'arg' does not
exist.
Program ref: arg.
Recommended actions
Check file or serial channel name.
Recovery: arg.
41677, Device access error
Description
Task: arg.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
Unable to write to file: arg, the disc is full.
Program ref: arg.
Recommended actions
Make sure there are enough free space on the disc.
Recovery: arg.
41678, Device access error
Description
Task: arg.
Unable to write to file: arg, the file is write-protected.
Program ref: arg.
Recommended actions
Remove the write protection of the file or select a different
filename.
Recovery: arg.
41679, Device access error
Description
Task: arg.
The maximum number of simultaneously opened files is
exceeded.
Program ref: arg.
Recommended actions
Close one or more I/O devices and try again.
Recovery: arg.
41680, String too long
Description
Task: arg.
The string arg exceeds the maximum number of characters
allowed for a module.
Program ref: arg.
Recommended actions
Change the string for module name.
Recovery: arg.
41682, Too many subscriptions from I/O
Description
Task: arg.
The number of simultaneous subscriptions on signal events
has been exceeded.
Program ref: arg.
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
Continues on next page
5.6 4 xxxx
Continued
295