Recommended actions
Make sure the fan cable is correctly connected. Make sure the
fan is free to rotate and that the air flow is not obstructed. Make
sure the drive module power supply output and input voltages
are within specified limits as detailed in the Trouble shooting
manual. Replace any faulty unit.
90310, SC arg Communication Failed
Description
An error occurred while trying to communicate with Safety
Controller (SC) arg.
Recommended actions
Check Safety Controller cabling. Check Safety Controller health.
Restart the robot controller, after performing recommended
actions.
90311, Enable 1 open
Description
The Enable 1 circuit monitoring the safety system has been
opened.
Consequences
The system goes to status SYS HALT.
Probable causes
There may be an internal fault in the safety system or the
internal supervision has detected a fault.
Recommended actions
Check all connections to the safety system. If faulty, replace
the faulty board.
90312, Enable 2 open
Description
The Enable 2 circuit monitoring the axis computer has been
opened.
Consequences
The system goes to status SYS HALT.
Probable causes
There may be a connection problem between main computer
and axis computer.
Recommended actions
Check all connections to the axis computer. Check cables
connected to the safety system.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
90313, Enable 1 supervision fault
Description
The Enable 1 circuit has been broken. This circuit monitors the
function of the safety system and the main computer.
Consequences
The system goes to status SYS HALT.
Probable causes
A fault, probably a software fault, has been detected by any of
the units supervised by the Enable 1 circuit.
Recommended actions
Attempt restarting by pressing the Motors ON button. If
restarting is IMPOSSIBLE it indicates a possible hardware fault.
If restarting is POSSIBLE, it indicates a software fault. In such
case, contact your local ABB representative. Determine which
unit is faulty by checking its indication LEDs. The LEDs are
described in the Trouble Shooting Manual. Replace the faulty
unit.
90314, Enable2 supervision fault
Description
The Enable 2 circuit to drive module 1 has been broken. This
circuit monitors e.g. the function of the safety system and the
axis computer.
Consequences
The system goes to status SYS HALT.
Probable causes
A fault, probably a software fault, has been detected by any of
the units supervised by the Enable 2 circuit.
Recommended actions
Attempt restarting by pressing the Motors ON button. If
restarting is IMPOSSIBLE it indicates a hardware fault in safety
system, axis computer. If restarting is POSSIBLE, it indicates
a software fault. In such case, contact your local ABB
representative. Determine which unit is faulty by checking its
indication LEDs. The LEDs are described in the Trouble
Shooting Manual. Replace the faulty unit.
90315, Enable2 Supervision fault
Description
The Enable 2 circuit to drive module 2 has been broken. This
circuit monitors e.g. the function of the safety system and the
axis computer.
Consequences
The system goes to status SYS HALT.
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
Continues on next page
5.9 9 xxxx
Continued
415