5 Troubleshooting by event log
5.10 11 xxxx
Continued
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error
handler.
110405, Current supervision
Description
Task: arg
arg
Current supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error
handler.
110406, Wirefeed supervision
Description
Task: arg
arg
Wirefeed supervision signal not set at start of welding.
Recommended actions
Check the wirefeed unit.
Recovery: You might want to handle errno arg in your error
handler.
110407, Wirestick supervision
Description
Task: arg
arg
Wirestick supervision signal set at start of welding.
Recommended actions
Check, if the wire got stuck at the object.
Recovery: You might want to handle errno arg in your error
handler.
110408, Arc ignition failed
Description
Task: arg
arg
Arc ignition failed at start of welding.
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error
handler.
Continues on next page
464
110409, Schedule strobe undefined
Description
Task: arg
arg
Schedule strobe undefined.
Recommended actions
Define a weld schedule strobe input.
Recovery: You might want to handle errno arg in your error
handler.
110410, Schedule transfer error
Description
Task: arg
arg
It was not possible to transfer the schedule.
Probable causes
The schedule port was busy with previous transfer.
Recommended actions
Recovery: You might want to handle errno arg in your error
handler.
110411, Process stopped
Description
Task: arg
arg
Process was stopped by the digital input 'stop process'.
Recommended actions
Check the digital input 'stop process'.
Recovery: You might want to handle errno arg in your error
handler.
110412, Arc fill ignition failed
Description
Task: arg
arg
Arc fill ignition failed.
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error
handler.
110413, Torch supervision
Description
Task: arg