112540, WDM Sample Frequency Error
Description
Sampling frequency is too fast for arg in task arg.
Consequences
No monitoring will occur.
Recommended actions
Please reduce sampling frequency to enable Weld Data
Monitoring.
112541, WDM welddata Change Error
Description
The weld parameters have changed since learning of seam arg
in task arg.
Consequences
No monitoring will occur.
Recommended actions
Please remove the stored signature and relearn with new
parameters. Or, reinstate old parameters.
112542, WDM Synchronizing Samples
Description
The segment number of the stored data is lagging the actual
sample. This is normal behavior associated with execution
stops.
Seamname: arg
Task: arg
Consequences
Some samples may have been ignored during the transition
between segments.
112543, WDM Synchronizing Samples
Description
The segment number of the actual sample is lagging the stored
data. This is normal behavior associated with execution stops.
Seamname: arg
Task: arg
Consequences
Some samples may have been ignored during the transition
between segments.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
112544, WDM Sample Distance Changed
Description
The weave parameters, or no-weave sample distance, have
changed since learning was finished for seam arg in task arg.
Consequences
No monitoring will occur.
Recommended actions
Please remove the stored signature and relearn with new
parameters. Or, reinstate old parameters.
112600, Init of communication interface failed
Description
Task arg
Communication interface could not be initialized.
Program Ref. arg
Recommended actions
Check communication settings and parameters and restart
application.
Recovery: arg
112601, Incorrect data received.
Description
The data received from remote system is incorrect. It is either
a data error of the remote system, or a wrong message was
received.
Recommended actions
Check data and program logic.
112602, Communication interface error.
Description
There is an error detected in the communication with the
external system.
Recommended actions
Check remote system and connection. Restart communication.
112603, Failed to access the config files
Description
The configuration and settings files for the communication
interface is not found in the HOME/GSI folder.
Recommended actions
Check that the HOME/GSI folder exists and that the
configuration and settings files can be found there. Restart
communciation.