Step 6 Apply ONU voice service profiles
After ONU voice service profiles are applied, if parameters in those profiles are changed, those
profiles must be reapplied so that the changed parameters can take effect.
1.
2.
Step 7 (Optional) Configure the H.248 user codec.
Run the mgpstnuser codec command to configure the H.248 user codec. The H.248 user codec
will not be configured independently in this example.
Step 8 Save the data.
huawei(config)#save
----End

12.4.1.7 Configuring the SIP-based Voice Service (on a Web Page)

The OLT is connected to the remote ONU through a GPON port to provide users with the IP-
based high-quality and low-cost VoIP service.
Issue 01 (2014-04-30)
ONT ID
Port ID
MG ID
Terminal ID
...//The rest of the response information is omitted.
huawei(config-if-gpon-0/1)#display mgpstnuser attribute 0 2 1
------------------------------------------------------------------------------
F/S/P
ONT ID
Port ID
MG ID
Terminal ID
...//The rest of the response information is omitted.
Apply an interface common profile.
Run the if-h248 attribute command to apply an interface common profile to an H.248
interface or configure the interface customized parameters, or run the ont-if-h248 bat-
apply command to bulk apply the interface common profiles to H.248 interfaces. If you
use these two commands to apply the interface common profiles or configure the interface
customized parameters repeatedly, the last configurations take effect.
In this example, the default interface common profile, namely interface common profile 1
is used.
Apply a POTS port profile.
Run the pstnport electric command to apply a POTS port profile to an H.248 interface or
configure the interface customized parameters, or run the ont-pstnport electric bat-
apply command to bulk apply the POTS port profiles to H.248 interfaces. If you use these
two commands to apply the POTS port profiles or configure the interface customized
parameters repeatedly, the last configurations take effect.
In this example, the default POTS port profile, namely POTS port profile 1 is used.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
12 FTTO Configuration(SOHO and SME)
: 1
: 1
: 1
: A0
: 0/1/0
: 2
: 1
: 1
: A1
1162

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartax ma5600tSmartax ma5608t

Table of Contents