9.2.12 1-axis speed control

Da. 8 Command speed
Positioning start signal
[Y10]
BUSY signal
[X10]
Positioning complete signal
( Md.31 Status:b15)
Cd.180 Axis stop
In speed control flag
( Md.31 Status:b0)
In "1-axis speed control" ("[Da.2] Control method" = Forward run: speed 1, Reverse
run: speed 1), control is carried out in the axis direction in which the positioning data
has been set by continuously outputting pulses for the speed set in "[Da.8] Command
speed" until the input of a stop command.
The two types of 1-axis speed control are "Forward run: speed 1" in which the control
starts in the forward run direction, and "Reverse run: speed 1" in which control starts in
the reverse run direction.
Operation chart
The following chart shows the operation timing for 1-axis speed control with axis 1
as the reference axis.
The "in speed control" flag ([Md.31] Status: b0) is turned ON during speed control.
The "Positioning complete signal" is not turned ON.