Signal name
Manual pulse
generator/Incremental
synchronous encoder
A phase/PLS
Differential-
output type
Manual pulse
generator/Incremental
synchronous encoder
B phase/SIGN
Manual pulse
generator/Incremental
synchronous encoder
Voltage-output
A phase/PLS
type/open-
Manual pulse
collector type
generator/Incremental
synchronous encoder
B phase/SIGN
External command/
Switching signal
Common (COM)
Forced stop input signal (EMI)
Forced stop input signal common
(EMI.COM)
Manual pulse generator power supply output
(+ 5VDC)
(5V)
Manual pulse generator power supply output
(GND)
(SG)
Pin No.
HAH
4
(A+)
(2) PLS/SIGN
Input the pulse signal for counting the increased/decreased pulse in the
pulse input (PLS). Input the signal for controlling forward run and reverse
HAL
run in the direction sign (SIGN).
5
(A-)
1) "[Pr.22] Input signal logic selection" is positive logic
• The motor will forward run when the direction sign is HIGH.
• The motor will reverse run when the direction sign is LOW.
2) "[Pr.22] Input signal logic selection" is negative logic
HBH
17
• The motor will forward run when the direction sign is LOW.
(B+)
• The motor will reverse run when the direction sign is HIGH.
[When increased]
HBL
18
(B-)
Positive
logic
HA
3
Negative
(A)
logic
Positioning
address
HB
16
(B)
• Input a control switching signal during speed-position or position-speed
(DI1)
11
switching control.
• Use this signal as the input signal of positioning start, speed change request,
(DI2)
24
skip request and mark detection from an external device.
(DI3)
12
Set the function to use this signal in "[Pr.42] External command function
selection".
(DI4)
25
(Note): Set the signal in "[Pr.95] External command signal selection".
13
• Common for external command/switching signals.
26
10
• This signal is input when batch forced stop is available for all axes of servo
amplifier.
EMI ON (Opened)
23
EMI OFF (24VDC input) : Forced stop release
• Power supply for manual pulse generator. (+ 5VDC)
1
(Note): This power supply is used for manual pulse generator. It must not be
14
used except for the manual pulse generator power supply.
• Power supply for manual pulse generator. (GND)
2
(Note): This power supply is used for manual pulse generator. It must not be
15
used except for the manual pulse generator power supply.
3 - 23
Chapter 3 Specifications and Functions
Signal details
PLS
HIGH
SIGN
PLS
LOW
SIGN
+1
+1+1
+1+1
+1
: Forced stop
[When decreased]
PLS
Positive
LOW
logic
SIGN
PLS
Negative
logic
HIGH
SIGN
Positioning
-1
-1 -1
address
-1 -1
-1