13.7.3 M code output function

Positioning start signal
BUSY signal
M code ON signal
( Md. 31 Status: b12)
Cd. 7 M code OFF request
Md. 25 Valid M code
Positioning
Da. 1 Operation pattern
The "M code output function" is used to command sub work (clamping, drill rotation,
tool replacement, etc.) related to the positioning data being executed.
When the M code ON signal ([Md.31] Status: b12) is turned ON during positioning
execution, a No. called the M code is stored in "[Md.25] Valid M code". These "[Md.25]
Valid M code" are read from the PLC CPU, and used to command auxiliary work. M
codes can be set for each positioning data. (Set in setting item "[Da.10] M
code/Condition data No./Number of LOOP to LEND repetitions" of the positioning
data.)
The timing for outputting (storing) the M codes can also be set in the "M code output
function".
The details shown below explain about the "M code output function".
[1] M code ON signal output timing
[2] M code ON signal OFF request
[3] Precautions during control
[4] Setting the M code output function
[5] Reading M codes
[1] M code ON signal output timing
The timing for outputting (storing) the M codes can be set in the "M code output
function". (The M code is stored in "[Md.25] Valid M code" when the M code ON
signal is turned ON.)
The following shows the two types of timing for outputting M codes: the "WITH
mode" and the "AFTER mode".
(1) WITH mode
The M code ON signal is turned ON at the positioning start, and the M code
is stored in "[Md.25] Valid M code".
[Y10 to Y1F]
[X10 to X1F]
V
1: m1 and m2 indicate set M codes.
Fig. 13.40 M code ON/OFF timing (WITH mode)
ON
OFF
ON
OFF
ON
OFF
0
1 0
1
m1
01
13 - 78
Chapter 13 Control Sub Functions
0
1 0
m2
1
Dwell time
00
t