Mitsubishi Electric MELSEC-Q Series User Manual page 780

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Classification
Error
Error name
of errors
code
Command in-position
925
width
Illegal torque limit
926
setting value
927
M code ON timing error
Speed switching mode
928
error
Interpolation speed
929
designation method
error
Current value update
930
request error
Manual pulse generator
932
input mode error
Speed-position function
Parameter
935
selection error
setting range
errors
External input signal
936
selection error
Forced stop
937
valid/invalid setting
error
Input signal logic
938
selection setting error
Acceleration time 1
950
setting error
Acceleration time 2
951
setting error
Acceleration time 3
952
setting error
Error
The set value of the detailed parameter 1
"Command in-position width" is outside the
setting range.
The set value of the detailed parameter 1
"Torque limit setting value" is outside the
setting range.
The set value of the detailed parameter 1 "M
code ON signal output timing" is outside the
setting range.
The set value of the detailed parameter 1
"Speed switching mode" is outside the
setting range.
The set value of the detailed parameter 1
"Interpolation speed designation method" is
outside the setting range.
The set value of the detailed parameter 1
"Feed current value during speed control"
is outside the setting range.
The set value of the detailed parameter 1
"Manual pulse generator/Incremental
synchronous encoder input selection" is
outside the setting range.
The detailed parameter 1 "Speed-position
function selection" is preset to 2 and the
following three conditions are not satisfied:
1) Unit is "degree".
2) Software stroke limits are invalid.
3) Update feed current value.
The set value of the detailed parameter 1
"External input signal selection" is outside
the setting range.
The set value of the detailed parameter 1
"Forced stop valid/invalid setting" is outside
the setting range.
The set values of the detailed parameter 1
"Input signal logic selection" are different in
the axis that uses the same input signal.
The set value of the detailed parameter 2
"Acceleration time 1" is outside the setting
range.
The set value of the detailed parameter 2
"Acceleration time 2" is outside the setting
range.
The set value of the detailed parameter 2
"Acceleration time 3" is outside the setting
range.
16 - 34
Chapter 16 Troubleshooting
Operation status at error occurrence
The READY signal [X0] is not turned ON.
When the PLC READY signal [Y0] is turned
from OFF to ON :The READY signal [X0] is
not turned ON.
At start
: The system does not start.
During operation : The system stops with the
setting (deceleration
stop/rapid stop) of the
detailed parameter 2 rapid
stop selection
(stop group 3).
(Note that the deceleration
stop only occurs during the
manual pulse generator
operation.)