Device
Signal name
No.
X10
Axis 1
BUSY
X11
Axis 2
(Note-1)
X12
Axis 3
X13
Axis 4
X14
Axis 5
X15
Axis 6
X16
Axis 7
X17
Axis 8
X18
Axis 9
X19
Axis 10
X1A
Axis 11
X1B
Axis 12
X1C
Axis 13
X1D
Axis 14
X1E
Axis 15
X1F
Axis 16
Important
(Note-1): The BUSY signal turns ON even when position control of movement amount 0 is
OFF: Not BUSY
ON: BUSY
• This signal turns ON at the start of positioning, HPR or JOG operation. It turns OFF
when the "[Da.9] Dwell time/JUMP destination positioning data No." has passed after
positioning stops. (This signal remains ON during positioning.)
• This signal turns OFF when the positioning is stopped with step operation.
• During manual pulse generator operation, this signal turns ON while the "[Cd.21]
Manual pulse generator enable flag" is ON.
• This signal turns OFF at error completion or positioning stop.
executed. However, since the ON time is short, the ON status may not to be detected
in the sequence program.
Chapter 3 Specifications and Functions
Details
3 - 16