Reading the monitor value
Monitoring is carried out with a hexadecimal display.
0
0
0
b15
b12
b8
b4
Buffer
0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0
memory
Not
Not used
used
Monitor
8
value
b0
Stored items
b0
In speed control flag
b1
Speed-position switching latch flag
b2
Command in-position flag
b3
HPR request flag
b4
HPR complete flag
b5
Position-speed switching latch flag
b9
Axis warning detection
b10
Speed change 0 flag
b12
M code ON
b13
Error detection
b14
Start complete
b15
Positioning complete
5 - 111