Basic Parameters 2 - Mitsubishi Electric MELSEC-Q Series User Manual

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

5.2.2 Basic parameters 2

Item
[Pr.8]
Speed limit value
[Pr.9]
Acceleration time 0
[Pr.10]
Deceleration time 0
[Pr.1] setting value
1: Range of speed limit value when "[Pr.83] Speed control 10 x multiplier setting for degree axis" is
2: Range of speed limit value when "[Pr.83] Speed control 10 x multiplier setting for degree axis" is
Setting value, setting range
Value set with GX Works2
The setting range differs depending on the "[Pr.1] Unit setting".
1 to 8388608 (ms)
1 to 8388608 (ms)
[Pr.8] Speed limit value
Set the maximum speed during positioning, HPR and speed-torque operations.
Value set with GX Works2 (unit)
0 : mm
0.01 to 20000000.00 (mm/min)
1 : inch
0.001 to 2000000.000 (inch/min)
2 : degree
0.001 to 2000000.000 (degree/min)
3 : PLS
1 to 1000000000 (PLS/s)
set to valid: 0.01 to 20000000.00 (degree/min).
set to valid: 1 to 2000000000 ( 10
[Pr.9] Acceleration time 0, [Pr.10] Deceleration time 0
"[Pr.9] Acceleration time 0" specifies the time for the speed to increase from zero
to the "[Pr.8] Speed limit value" ("[Pr.31] JOG speed limit value" at JOG operation
control).
"[Pr.10] Deceleration time 0" specifies the time for the speed to decrease from the
"[Pr.8] Speed limit value" ("[Pr.31] JOG speed limit value" at JOG operation
control) to zero.
Velocity
Pr.9
Acceleration time 0
1) If the positioning speed is set lower than the parameter-defined speed limit
value, the actual acceleration/deceleration time will be relatively short. Thus, set
the maximum positioning speed equal to or only a little lower than the
parameter-defined speed limit value.
2) These settings are valid for HPR, positioning and JOG operations.
3) When the positioning involves interpolation, the acceleration/deceleration time
defined for the reference axis is valid.
Chapter 5 Data Used for Positioning Control
Value set with sequence
program
1 to 8388608 (ms)
1 to 8388608 (ms)
-2
degree/min)
Pr.8
Speed limit value
Positioning speed
Actual
acceleration
time
Deceleration time 0
Pr.10
5 - 26
Default
Buffer memory address
value
200000
1000
1000
Value set with sequence program (unit)
1 to 2000000000 (×10
1 to 2000000000 (×10
1 1 to 2000000000 (×10
1 to 1000000000 (PLS/s)
Time
Actual deceleration time
10+150n
11+150n
12+150n
13+150n
14+150n
15+150n
n: Axis No.-1
-2
mm/min)
-3
inch/min)
-3
degree/min)
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-qd77gf4Melsec-qd77gf8Melsec-qd77gf16

Table of Contents