Setting item
[Cd.7] M code OFF request
[Cd.8] External command valid
[Cd.9] New current value
[Cd.10] New acceleration time value
[Cd.11] New deceleration time value
The M code ON signal turns OFF.
Fetch cycle: Operation cycle
Validates or invalidates external command signals.
Fetch cycle: At request by external command signal
When changing the "feed current value" using the start No. "9003", use this data
item to specify a new feed value.
The setting value range differs according to the "[Pr.1] Unit setting".
mm
[Pr.1] Unit
(  10
-1
setting
µm)
-2147483648
Setting range
to
2147483647
Fetch cycle: At change request
When changing the acceleration time during a speed change, use this data item
to specify a new acceleration time.
[Cd.10] setting range (unit)
0 to 8388608 (ms)
Fetch cycle: At change request
When changing the deceleration time during a speed change, use this data item
to specify a new deceleration time.
[Cd.11] setting range (unit)
0 to 8388608 (ms)
Fetch cycle: At change request
5 - 136
Chapter 5 Data Used for Positioning Control
Setting details
inch
degree
(  10
-5
(  10
-5
inch)
degree)
-2147483648
to
0 to 35999999
2147483647
PLS
(PLS)
-2147483648
to
2147483647