5.2.6 HPR detailed parameters

Item
[Pr.50]
Setting for the movement
amount after proximity dog
ON [RJ010 mode]
[Pr.51]
HPR acceleration time
selection
[Pr.52]
HPR deceleration time
selection
[Pr.53]
HP shift amount
[RJ010 mode]
[Pr.54]
HPR torque limit value
[RJ010 mode]
[Pr.55]
Operation setting for
incompletion of HPR
[Pr.56]
Speed designation during
HP shift [RJ010 mode]
[Pr.57]
Dwell time during HPR retry
[RJ010 mode]
Setting value, setting range
Value set with GX Works2
The setting value range differs depending on the "[Pr.1] Unit
setting".
0 : [Pr.9] Acceleration time 0
1 : [Pr.25] Acceleration time 1
2 : [Pr.26] Acceleration time 2
3 : [Pr.27] Acceleration time 3
0 : [Pr.10] Deceleration time 0
1 : [Pr.28] Deceleration time 1
2 : [Pr.29] Deceleration time 2
3 : [Pr.30] Deceleration time 3
The setting value range differs depending on the "[Pr.1] Unit
setting".
1 to 1000 (%)
0 : Positioning control is not
executed.
1 : Positioning control is
executed.
0 : HPR speed
1 : Creep speed
0 to 65535 (ms)
Chapter 5 Data Used for Positioning Control
Value set with sequence
program
0
1
2
3
0
1
2
3
1 to 1000 (%)
0
1
0
1
0 to 65535 (ms)
0 to 32767
: Set as a
decimal
32768 to 65535 : Convert into
hexadecimal
and set
5 - 56
Default
Buffer memory address
value
80+150n
0
81+150n
0
82+150n
0
83+150n
84+150n
0
85+150n
300
86+150n
0
87+150n
0
88+150n
0
89+150n
n: Axis No.-1