Mitsubishi Electric MELSEC-Q Series User Manual page 824

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

When using the internal power supply
Simple Motion module side
10126-3000PE (Connector)
10326-52F0-008 (Connector case)
HBL
18
HBH
17
HAL
5
HAH
4
HB
16
HA
3
(Note-2)
15
SG
(Note-3)
5V
14
(Note-2)
2
SG
(Note-3)
5V
1
EMI
10
EMI.COM
23
DI1
11
COM
13
DI3
12
DI2
24
COM
26
DI4
25
DICOM
(Note-1)
FG
Shell
(Note-1): Ground FG terminal on the used equipment side. Also, connect it to the shell of connector side.
(Note-2): Be sure to connect the 0 V (-) of the manual pulse generator/incremental synchronous encoder
(Note-3): Be sure not to be used except for supplying the power to the manual pulse generator.
: Twisted pair cable
and the SG of the Simple Motion module.
Appendix - 24
Solderless terminal
HB
Voltage-output/open-collector type
HA
Manual pulse generator/
incremental synchronous encoder side
(Note-2)
0V
(Note-3)
5V
(Note-1)
FG
EMI
Forced stop input
EMI.COM
DI1
DI3
External command/switching
DI2
DI4
DICOM
(Note-1)
FG
Appendices

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-qd77gf4Melsec-qd77gf8Melsec-qd77gf16