Mitsubishi Electric MELSEC-Q Series User Manual page 761

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Related buffer memory address
105
78+150n
74+150n
75+150n
80+150n
81+150n
74+150n
75+150n
4300+100n
4300+100n
Set range
(Setting with sequence program)
<HPR retry>
0, 1
<HPR speed>
1 to 1000000000 [PLS/s]
-2
1 to 2000000000 [ 10
mm/min or others]
<Movement amount setting after proximity
dog ON>
0 to 2147483647
<HPR speed>
1 to 1000000000 [PLS/s]
-2
1 to 2000000000 [ 10
mm/min]
<Positioning start No.>
1 to 600, 7000 to 7004, 9001 to 9004
<Positioning start No.>
1 to 600, 7000 to 7004, 9001 to 9004
16 - 15
Chapter 16 Troubleshooting
Remedy
Turn ON the PLC READY signal [Y0] with the BUSY signals
of all axes OFF.
Do not request the start when the axis operation state is other
than "standby", "stop", and "step standby".
Review the content of the positioning or "[Pr.96] Operation
cycle setting" longer than the current setting.
• Validate the HPR retry function (set value: 1). (Refer to
Section 13.2.1).
• Move the work piece from the current position (on HP) using
the manual control operation (refer to Chapter 11), then carry
out a machine HPR again.
• Lower the HPR speed.
• Increase the dog signal input time.
(Refer to Section 8.2.3)
• Calculate the movement distance using a speed limit, HPR
speed, and deceleration time, and set the movement amount
after proximity dog ON so that the distance becomes a
deceleration distance or longer.
• Lower the HPR speed.
• Adjust the proximity dog position so that the movement
amount after proximity dog ON becomes longer. (Refer to
Section 8.2.4, 8.2.5)
Execute the machine HPR (positioning start No. 9001). (Refer
to Section 8.2)
Start the machine HPR (positioning start No. 9001) again.
(Refer to Section 8.2)
Turn the motor more than one revolution using JOG or
positioning operation.
• Execute HPR again.
• When the servo parameter "Function selection C-4 (PC17)"
is changed to "1: Not need to pass motor Z-phase after the
power supply is switched on", transfer the parameter from
the Simple Motion module to the servo amplifier and turn the
power supply of the servo amplifier OFF. Then, turn it ON
and execute HPR again.
• Execute HPR again.
• Adjust the servo gain and in-position range, and execute
HPR again.
n: Axis No.-1