[Wiring example of shielded cable]
To Simple Motion module
[Processing example of shielded cables]
Connections of FG wire and each shielded cable
Remove the covering from all shielded
cables and bind the appeared shield
with a conductive tape.
The following shows a wiring example for noise reduction in the case when the
connector (LD77MHIOCON) is used.
For forced stop input signal
/External command signal/Switching signal
Connector
(LD77MHIOCON)
Chapter 4 Installation, Wiring and Maintenance of the Product
Shielded cable
The shield must be grounded in the cable connector shell.
Wrap the coated part with a heat
contractile tube.