Mitsubishi Electric MELSEC-Q Series User Manual page 475

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Setting item
[Da.1] Operation pattern
[Da.2] Control method
[Da.3] Acceleration time No.
[Da.4] Deceleration time No.
Positioning address/
[Da.6]
movement amount
[Da.7] Arc address
[Da.8] Command speed
Dwell time/JUMP
[Da.9]
destination positioning
data No.
M code/Condition
data No./Number of
[Da.10]
LOOP to LEND
repetitions
Axis to be interpolated
[Da.20]
No.1
Axis to be interpolated
[Da.21]
No.2
Axis to be interpolated
[Da.22]
No.3
(Note): Refer to Section 5.3 "List of positioning data" for information on the setting details.
Positioning data setting examples
[When "1-axis speed control (forward run: speed 1)" is set in the positioning data
No. 1 of axis 1]
Setting example
Positioning complete
Forward run speed 1 Set 1-axis speed control.
1
0
6000.00mm/min
10
Chapter 9 Major Positioning Control
Setting other than "Positioning complete" is not possible in
speed control.
Designate the value set in "[Pr.25] Acceleration time 1" as the
acceleration time at start.
Designate the value set in "[Pr.10] Deceleration time 0" as the
deceleration time at deceleration.
Setting not required (setting value is ignored).
Set the speed to be commanded.
Setting not required (setting value is ignored).
Set this when other sub operation commands are issued in
combination with the No. 1 positioning data. ("[Pr.18] M code
ON signal output timing" setting only possible in the WITH
mode.)
Setting not required (setting value is ignored).
9 - 75
Setting details

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-qd77gf4Melsec-qd77gf8Melsec-qd77gf16

Table of Contents