Setting item
Number of mark
[Cd.800]
detection clear
request
Mark detection
[Cd.801]
invalid flag
(2) Mark detection control data
Setting details/setting value
Set "1" to execute "0" clear of number of mark detections.
"0" is automatically set after completion by "0" clear of
number of mark detections.
1: 0 clear of number of mark detections
Fetch cycle: Operation cycle
Set this flag to invalidate mark detection temporarily.
1
: Mark detection: Invalid
Others : Mark detection: Valid
Fetch cycle: Operation cycle
[Cd.800] Number of mark detection clear request
Set "1" to execute "0" clear of "[Md.800] Number of mark detection". "0" is
automatically set after completion by "0" clear of "[Md.800] Number of mark
detection".
[Cd.801] Mark detection invalid flag
Set "1" to invalidate mark detection temporarily. The mark detection signal during
invalidity is ignored.
14 - 30
Chapter 14 Common Functions
Default
Buffer memory address
value
0
54640+10k
0
54641+10k
k: Mark detection setting No.-1