8.4 Selection of the HPR setting condition

8.4.1 Outline of the HPR setting condition

Setting item
Function selection C-4
(PC17)
: Refer to Section 5.2.8 "Servo parameters" for information on the storage details.
If executing the home position return (HPR) when selecting "0: Need to pass servo
motor Z-phase after power on" with the servo parameter of the servo amplifier
"Function selection C-4 (PC17)", it is necessary that the servomotor has been rotated
more than one revolution and passed the Z phase (Motor reference position signal)
and that the zero point pass signal ([Md.108] Servo status (low-order buffer memory
address): b0) has turned ON.
When selecting "1: Not need to pass servo motor Z-phase after power on" with
"Function selection C-4 (PC17)", it is possible to turn the zero point pass signal
([Md.108] Servo status (low-order buffer memory address): b0) ON without passing the
zero point.
[Md.108] Servo status: b0
Data setting
To select the "HPR setting condition", set the "servo parameter" shown in the
following table.
Servo parameters are set for each axis.
The "HPR setting condition" is stored into the following buffer memory addresses.
Setting
value
0 : Need to pass servo motor Z-phase after
1 : Not need to pass servo motor Z-phase
Precautions during operation
(1) Set "Function selection C-4 (PC17)", and then turn off the power supply of the
servo amplifier once and switch it on again to make that parameter setting
valid.
Buffer memory address (low-order)
Setting details
power on
after power on
8 - 23
Chapter 8 HPR Control
2476+100n
Buffer memory address
28480+100n
n: Axis No.-1
n: Axis No.-1