Mitsubishi Electric MELSEC-Q Series User Manual page 227

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Reading the monitor value
Monitoring is carried out with a hexadecimal display.
Monitor
value
Monitoring is carried out with a decimal display.
Monitor
value
Monitoring is carried out with a decimal display.
Monitor value
Monitoring is carried out with a decimal display.
Monitor
R
Decimal integer
value
value
Unit conversion
R
Actual
Current speed
Md.27
value
Axis warning No.
For details of warning codes,
refer to Section 16.5 "List of
warnings".
M code No.
(0 to 65535)
Axis operation status
-2: Step standby
-1: Error
0: Standby
1: Stopped
2: Interpolation
3: JOG operation
4: Manual pulse generator operation
5: Analyzing
6: Special start standby
7: HPR
8: Position control
9: Speed control
10: Speed control in speed-position switching control
11: Position control in speed-position switching control
12: Position control in position-speed switching control
13: Speed control in position-speed switching control
15: Synchronous control
20: Servo amplifier has not been connected/
servo amplifier power OFF
21: Servo OFF
30: Control mode switch
31: Speed control
32: Torque control
Unit conversion table
Md.27
m
10
m
-2
-3
-3
0
: When " Pr.83 Speed
control 10 x multiplier
setting for degree axis"
is valid: "-2"
5 - 107
Chapter 5 Data Used for Positioning Control
Default
value
0000H
0
0
)
Unit
mm/min
0
inch/min
degree/min
PLS/s
Buffer memory address
2407+100n
2408+100n
2409+100n
2410+100n
2411+100n
n: Axis No.-1