Acceleration/Deceleration Processing Function - Mitsubishi Electric MELSEC-Q Series User Manual

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

13.7.6 Acceleration/deceleration processing function

Setting item
[Pr.9]
Acceleration time 0
[Pr.25] Acceleration time 1
[Pr.26] Acceleration time 2
[Pr.27] Acceleration time 3
[Pr.10] Deceleration time 0
[Pr.28] Deceleration time 1
[Pr.29] Deceleration time 2
[Pr.30] Deceleration time 3
: Refer to Section 5.2 "List of parameters" for setting details.
The "acceleration/deceleration processing function" adjusts the
acceleration/deceleration of each control to the acceleration/deceleration curve
suitable for device.
Setting the acceleration/deceleration time changes the slope of the
acceleration/deceleration curve.
The following two methods can be selected for the acceleration/deceleration curve:
Trapezoidal acceleration/deceleration
S-curve acceleration/deceleration
Refer to Section 12.1 "Speed-torque control" for acceleration/deceleration processing
of speed-torque control.
The details shown below explain about the "acceleration/deceleration processing
function".
[1] "Acceleration/deceleration time 0 to 3" control details and setting
[2] "Acceleration/deceleration method setting" control details and setting
[1] "Acceleration/deceleration time 0 to 3" control details and setting
In the Simple Motion module, four types each of acceleration time and
deceleration time can be set. By using separate acceleration/deceleration times,
control can be carried out with different acceleration/deceleration times for
positioning control, JOG operation, HPR, etc.
Set the required values for the acceleration/deceleration time in the parameters
shown in the following table, and write them to the Simple Motion module.
The set details are validated when written to the Simple Motion module.
Setting
value
Setting details
Set the acceleration time at a value within the range
of 1 to 8388608 ms.
Set the deceleration time at a value within the range
of 1 to 8388608 ms.
13 - 91
Chapter 13 Control Sub Functions
Factory-set
initial value
1000
1000
1000
1000
1000
1000
1000
1000