Mitsubishi Electric MELSEC-Q Series User Manual page 260

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Setting item
[Cd.16] Inching movement amount
[Cd.17] JOG speed
[Cd.18] Interrupt request during
continuous operation
Use this data item to set the amount of movement by inching.
The machine performs a JOG operation if "0" is set.
Set a value within the following range:
mm
[Pr.1] Unit
(  10
-1
setting
µm)
Setting range
0 to 65535
Fetch cycle: At start
Use this data item to set the JOG speed.
The setting value range differs according to the "[Pr.1] Unit setting".
mm
[Pr.1] Unit
-2
setting
(
10
mm/min)
1 to
Setting range
2000000000
: When "[Pr.83] Speed control 10 x multiplier setting for degree axis" is valid,
this will be the setting range
Fetch cycle: At start
To interrupt a continuous operation, set "1" to this data item.
After processing the interruption request ("1"), the Simple Motion module
automatically resets the value to "0".
Fetch cycle: Operation cycle
5 - 140
Chapter 5 Data Used for Positioning Control
Setting details
inch
degree
(  10
-5
(  10
-5
inch)
degree)
0 to 65535
0 to 65535
inch
degree
-3
(
10
inch/min)
-3
(
10
degree/min)
1 to
1 to
2000000000
2000000000
to 2000000000 (  10
-2
degree/min).
1
PLS
(PLS)
0 to 65535
PLS
(PLS/s)
1 to 1000000000

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-qd77gf4Melsec-qd77gf8Melsec-qd77gf16

Table of Contents