Independent positioning control and continuous positioning control
The Simple Motion module performs positioning according to the user-set positioning
data, which is a set of information comprised of the control method (position control,
speed control, speed-position switching control), positioning address, operation pattern,
and so on.
Up to 600 of positioning data are assigned respectively to positioning data Nos. 1 to
600 per axis and registered to the Simple Motion module.
The operation pattern set in each positioning data by the user determines whether to
perform positioning operation with one positioning data item or to perform continuous
positioning operation with multiple positioning data items.
(1) Independent positioning control (operation pattern = 00: positioning
complete)
The operation completed upon completion of positioning for the specified
positioning data. The positioning completion of this operation pattern is also used
as the operation pattern for the last positioning data of continuous positioning and
continuous path positioning.
V
Positioning start signal
Positioning start
complete signal
BUSY signal
Positioning complete
signal
Positioning complete (00)
ON
OFF
ON
OFF
ON
OFF
OFF
1 - 13
Chapter 1 Product Outline
Dwell time
t
(By the sequence
program creation)
ON