Mitsubishi Electric MELSEC-Q Series User Manual page 740

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Setting value
0
Feed current value
1
Feed machine value
2
Real current value
3
Servo input axis current value
6
Synchronous encoder axis current value
Synchronous encoder axis current value
7
per cycle
Current value after composite main
8
shaft gear
Current value per cycle after main shaft
9
gear
Current value per cycle after auxiliary
10
shaft gear
11
Cam axis current value per cycle
Cam axis current value per cycle (Real
12
(Note)
position)
[Pr.803] Mark detection data axis No.
Set the axis No. of data that latched at mark detection.
[Pr.802] Mark detection data type
Data name
(Note): Cam axis current value per cycle that considered delay of the servo system.
If a value other than the above is set, the warning "Outside mark detection data
axis No. setting range" (warning code: 132) occurs and the target mark detection
is not available.
[Pr.804] Mark detection data buffer memory No.
Set the No. of optional 2 words buffer memory that latched at mark detection.
Set this No. as an even No.
If a value other than the above is set, the warning "Outside mark detection data
buffer memory No. setting range" (warning code: 133) occurs and the target mark
detection is not available.
Unit
-1
-5
10
[µm], 10
[inch],
-5
10
[degree], [PLS]
Synchronous encoder
axis position unit
Main input axis position
unit
Cam axis cycle unit
14 - 28
Chapter 14 Common Functions
[Pr.803] Mark detection data axis No.
QD77GF4
QD77GF8 QD77GF16
1 to 4
1 to 8
801 to 804
1 to 4
1 to 8
1 to 16
1 to 16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-qd77gf4Melsec-qd77gf8Melsec-qd77gf16

Table of Contents