This command describes an alarm contact input pin. The description provides an indication
of the usage or attribute of the pin. It is stored in the CLI configuration file and helps the user
in identifying the purpose of the pin.
normal-state
Syntax
normal-state [open | closed]
Context
config>system>alarm-contact-input
Platforms
7210 SAS-M (network and access-uplink), 7210 SAS-T (network and access-uplink),
7210 SAS-Mxp, 7210 SAS-R6 and 7210 SAS-R12
Description
This command configures the normal state to be associated with the alarm-contact input.
When the system detects a transition from the normal state, an alarm is generated. The alarm
is cleared when the system detects a transition is back to the normal state.
Parameters
open — Specifies an open normal-state. When the system detects a transition to the
closed — Specifies a closed normal-state. When the system detects a transition to the
shutdown
Syntax
[no] shutdown
Context
config>system>alarm-contact-input
Platforms
7210 SAS-M (network and access-uplink), 7210 SAS-T (network and access-uplink),
7210 SAS-Mxp, 7210 SAS-R6 and 7210 SAS-R12
Description
This command stops tracking the state changes associated with the alarm contact input.The
system does not generate or clear the alarms for the alarm-contact input, but if an alarm is
generated for the alarm-contact-input, the system clears the alarm when the shutdown
command is executed.
The no form of this command starts tracking the state changes associated with the alarm
contact input.
Default
shutdown
trigger-alarm-msg
Syntax
[no] trigger-alarm-msg {alarm-msg-text}
486
closed state, an alarm is generated. The alarm is cleared when the system detects a
transition back to the open state.
open state, and alarm is generated. The alarm is cleared when the system detects a
transition back to the closed state.
Use subject to Terms available at: www.nokia.com