System Management
6.12.2.1.2
boot-bad-exec
Syntax
boot-bad-exec file-url
no boot-bad-exec
Context
config>system
Platforms
Supported on all 7210 SAS platforms as described in this document, including platforms
configured in the access-uplink operating mode
Description
This command configures a URL for a CLI script to exec following a failure of a boot-up
configuration. The command specifies a URL for the CLI scripts to be run following the
completion of the boot-up configuration. A URL must be specified or no action is taken.
The commands are persistent between router reboots and are included in the configuration
saves (admin save).
See the
file as if they were commands entered at the console.
Default
no boot-bad-exec
Parameters
file-url — Specifies the location and name of the CLI script file executed following failure
394
System Information Commands
exec
command for related commands. This command executes the contents of a text
of the boot-up configuration file execution. When this parameter is not specified, no
CLI script file is executed.
Values
file url — local-url | remote-url: 255 chars max
local-url — [cflash-id/ | usb-flash-id][file-path]
remote-url — [{ftp://} login:pswd@remote-locn/][file-path]
remote-locn — [hostname | ipv4-address]
usb-flash-id — uf1: (7210 SAS-M, 7210 SAS-T,
cflash-id — cf1:, cf2: (7210 SAS-T, 7210 SAS-Mxp,
Use subject to Terms available at: www.nokia.com
7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
ipv4-address — a.b.c.d
7210 SAS-Mxp, 7210 SAS-Sx 1/10GE:
standalone and standalone-VC, and
7210 SAS-Sx 10/100GE)
uf1:, uf1-A:, uf1-B: (7210 SAS-R6 and
7210 SAS-R12)
7210 SAS-Sx 10/100GE, and 7210 SAS-Sx/
S 1/10GE: standalone and standalone-VC)
cf2:, cf2-A:, cf2-B: (7210 SAS-R6 and
7210 SAS-R12)
© 2021 Nokia.
Configuration Guide
3HE 17358 AAAB TQZZA