System Management
rising-event rmon-event-id — Specifies the action to be taken when a rising threshold
rising-threshold threshold — Specifies a threshold for the sampled statistic. A single
falling-event rmon-event-id — Specifies the action to be taken when a falling threshold
falling-threshold threshold — Specifies a threshold for the sampled statistic. A single
424
crossing event occurs.
If there is no corresponding event configured for the specified rmon-event-id, then
no association exists and no action is taken.
If the rising-event rmon-event-id has a value of zero (0), no associated event exists.
If a rising-event rmon-event-id is configured, the CLI requires a rising threshold to
also be configured.
Default
0
Values
0 to 65535
threshold crossing event is generated when the current sampled value is greater than
or equal to this threshold, and the value at the last sampling interval was less than
this threshold. A single threshold crossing event will also be generated if the first
sample taken is greater than or equal to this threshold and the associated startup-
alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be
generated until the sampled value falls below this threshold and reaches less than or
equal the falling threshold value.
Values
–2147483648 to 2147483647
Default
0
crossing event occurs. If there is no corresponding event configured for the specified
rmon-event-id, then no association exists and no action is taken. If the falling-event
has a value of zero (0), no associated event exists.
If a falling event is configured, the CLI requires a falling-threshold to also be
configured.
Values
–2147483648 to 2147483647
Default
0
threshold crossing event is generated when the current sampled value is less than
or equal to this threshold, and the value at the last sampling interval was greater than
this threshold. A single threshold crossing event will also be generated if the first
sample taken is less than or equal to this threshold and the associated startup-alarm
is equal to falling or either.
After a rising threshold crossing event is generated, another such event will not be
generated until the sampled value rises above this threshold and reaches greater
than or equal the rising-threshold value.
Values
–2147483648 to 2147483647
Default
0