System Management
6.11.6.2
7210 SAS hardware supports alarm contact inputs that allow the operator to monitor
and report changes in external environmental conditions. In a remote or outdoor
deployment, alarm contact inputs allow the operator to detect conditions, for
example, air conditioner fault, open door.
You can configure generation of events when alarm contact inputs transition
between the open and close states. For each generated event, you can specify the
following:

6.11.7 Configuring 1830 VWM

The following is a sample output for the creation of a vwm-shelf.
Note: Card 1 corresponds to slot #1 and card 2 corresponds to slot #2 on the 1830 CWDM
device. The optical modules or line cards are inserted into these slots.
*A:NS1333C2676# configure system vwm-shelf 3 vwm-type ec-cw create
*A:NS1333C2676>configure>system>vwm-shelf$ info
----------------------------------------------
----------------------------------------------
*A:NS1333C2676>configure>system>vwm-shelf$ info detail
----------------------------------------------
*A:NS1333C2676>configure>system>vwm-shelf$
*A:7210 SAS>show system vwm-shelf 7
===========================================================================
Shelf Summary
362

System Alarm Contact Inputs

• action associated with each state transition
• severity associated with each state transition
• log message associated with each state transition
no shutdown
card 1
shutdown
no card-type
exit
card 2
shutdown
no card-type
exit
no shutdown