interval seconds — Specifies the polling period over which the data is sampled and
rmon-event-type — Specifies the type of notification action to be taken when this event
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first
cflash-cap-alarm
Syntax
cflash-cap-alarm cflash-id rising-threshold threshold [falling-threshold threshold]
no cflash-cap-alarm cflash-id
Context
config>system>thresholds
Platforms
Supported on all 7210 SAS platforms as described in this document, including platforms
configured in the access-uplink operating mode
Description
This command enables capacity monitoring of the compact flash specified in this command.
The severity level is alarm. Both a rising and falling threshold can be specified.
The no form of this command removes the configured compact flash threshold alarm.
Parameters
cflash-id — Specifies the name of the cflash device to be monitored.
3HE 17358 AAAB TQZZA
compared with the rising and falling thresholds.
Values
1 to 2147483647
occurs.
Values
log — An entry is made in the RMON-MIB log table for each event
occurrence. This does not create a TiMOS logger entry. The RMON-
MIB log table entries can be viewed using the show system
thresholds command.
trap — A TiMOS logger event is generated. The TiMOS logger utility
then distributes the notification of this event to its configured log
destinations which may be CONSOLE, telnet session, memory log,
cflash file, syslog, or SNMP trap destinations logs.
both — Both an entry in the RMON-MIB logTable and a TiMOS
logger event are generated.
none — No action is taken.
Default
both
created. If the first sample is greater than or equal to the rising threshold value and
startup-alarm is equal to rising or either, a single rising threshold crossing event is
generated. If the first sample is less than or equal to the falling threshold value and
startup-alarm is equal to falling or either, a single falling threshold crossing event
is generated.
Values
rising, falling, either
Default
either
interval seconds [rmon-event-type] [startup-alarm alarm-type]
Values
uf1: (7210 SAS-M)