Manually Configuring Nodes To Boot As Cpm-Imm In A Vc - Nokia 7210 Configuration Manual

Service access switch 7210 sas-m, t, r6, r12, mxp, sx, s basic system
Hide thumbs Also See for 7210:
Table of Contents

Advertisement

Virtual Chassis
5.2.2 Manually Configuring Nodes to Boot as CPM-IMM in
The CPM-IMM nodes are configured through the BOF and do not require further
configuration to be part of the VC. Perform the following steps to manually boot and
configure CPM-IMM nodes in a VC.
Step 1. Identify the two nodes that will take on the CPM role.
Step 2. Ensure there is console access to the CPM nodes to drive the boot
Step 3. Ensure the CPM nodes are powered on.
Step 4. Ensure that the SD card delivered with the software license containing the
Step 5. Manually interrupt the boot process at the boot loader BOF prompt and
228
The slot number identifies a specific node in the VC (similar to the slot ID of a
card in a chassis-based system) and is used in addressing service objects
created during provisioning. The slot number also is used to light up the correct
LED on the front-panel of the node, enabling operators to see which slot is
configured with the VC node (the stack LED also denotes that the node is part
of a VC and is fully functional). The slot number of the active and standby CPM-
IMMs can be set to any number from 1 to 8, as long as it is not in use by another
VC member node. An arbitration process during the boot phase ensures that
one of the CPM nodes is the active CPM and the other is the standby CPM.
The MAC address must match the base MAC address printed on the label of the
chassis.
• eth-mgt-address
Configure the management IP address for the two CPM nodes using the
command bof>eth-mgmt-address ip-prefix/ip-prefix-length [active | standby].
The Ethernet management IP address configured as active provides the IP
address of the active node, which a management station can use to operate the
stack. The management IP address configured as standby provides
connectivity to the standby node.
a VC
process. See the following for information:
Console,
7210 SAS-S 1/10GE Console
Console
Port.
boot loader (boot.tim) and TiMOS software is installed in the SD card slot.
configure the following:
i. specify standalone-vc for the chassis-role parameter
ii. specify a name for the vc-stack-name parameter
iii. specify cpm-imm for the vc-stack-node-type parameter
Use subject to Terms available at: www.nokia.com
7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
© 2021 Nokia.
Configuration Guide
Procedure to Connect to a
Port, and
7210 SAS-Sx 10/100GE
3HE 17358 AAAB TQZZA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7210 sas-mxp7210 r67210 r127210 s7210 sx7210 t

Table of Contents