Table 42 Card Type Acronyms For 1830 Cwdm Devices - Nokia 7210 Configuration Manual

Service access switch 7210 sas-m, t, r6, r12, mxp, sx, s basic system
Hide thumbs Also See for 7210:
Table of Contents

Advertisement

System Management
Context
config>system>vwm-shelf>card
Platforms
7210 SAS-M (network and access-uplink), 7210 SAS-T (network and access-uplink),
7210 SAS-Mxp, 7210 SAS-R6 and 7210 SAS-R12
Description
This command provides the user a better control over the modules plugged into the 1830
CWDM device slots. The user can preprovision acceptable modules by configuring the card-
type parameter with the appropriate card-type vwm-acronym. The modules are identified
using the acronyms listed below.
The 7210 SAS validates the configured card-types with the card-type acronym retrieved from
the clip-on device and checks the following.
If the user set the card to administratively up and the module is missing, the 7210 SAS raises
an event/trap. The event results in a major alarm with the major LED set to the appropriate
color. If the user has preprovisioned the card and administratively shut it down, the software
does not attempt to match the module's identifier (if the module is equipped in the slot) and
clears any pending alarms. The software retrieves any information about the equipped
module to aid the user with provisioning.
The no form of this command removes and clears the card-type information. Until the card-
type is provisioned, the software does not raise any events/traps/alarms for the card and
clears all pending events/traps/alarms/LEDs.
Table 42
Product overview guide for 1830 VWM. This is used to preprovision the acceptable modules
that can be equipped in the slots of the clip-on device.
Table 42
406
• If the configured card-type matches the card type acronym retrieved from the clip-on
device, the 7210 SAS allows management of the module.
• If the configured card-type does not match the card type acronym retrieved from the clip-
on device, the 7210 SAS raises an event to alert the user of mismatch in configuration.
The event results in a major alarm with the major LED set. In such a case, the card status
displays "Provisioning Mismatch" error.
• The mismatch event/trap is cleared if the module is replaced with the one that has a
correct card type acronym. Any pending trap/event, major alarm and major LED is
cleared.
lists the acronyms defined by the optical group. For more information, see the
Card Type Acronyms for 1830 CWDM Devices
Module Description
1830 VWM 1-CH CWDM FILTER (AB VARIANT) - CH1 (1471nm)
1830 VWM 1-CH CWDM FILTER (AC VARIANT) - CH1 (1491nm)
1830 VWM 1-CH CWDM FILTER (AD VARIANT) - CH1 (1511nm)
1830 VWM 1-CH CWDM FILTER (AE VARIANT) - CH1 (1531nm)
1830 VWM 1-CH CWDM FILTER (AF VARIANT) - CH1 (1551nm)
Use subject to Terms available at: www.nokia.com
7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
© 2021 Nokia.
Configuration Guide
Acronym
SFC1A
SFC1B
SFC1C
SFC1D
SFC1E
3HE 17358 AAAB TQZZA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7210 sas-mxp7210 r67210 r127210 s7210 sx7210 t

Table of Contents