Nokia 7210 Configuration Manual page 419

Service access switch 7210 sas-m, t, r6, r12, mxp, sx, s basic system
Hide thumbs Also See for 7210:
Table of Contents

Advertisement

7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
Configuration Guide
memory-use-alarm
Syntax
memory-use-alarm rising-threshold threshold [falling-threshold threshold] interval
no memory-use-alarm
Context
config>system>thresholds
Platforms
Supported on all 7210 SAS platforms as described in this document, including platforms
configured in the access-uplink operating mode
Description
The memory thresholds are based on monitoring the TIMETRA-SYSTEM-MIB
sgiMemoryUsed object. This object contains the amount of memory currently used by the
system. The severity level is Alarm. The absolute sample type method is used.
The no form of this command removes the configured memory threshold warning.
Parameters
rising-threshold threshold — Specifies a threshold for the sampled statistic. A single
falling-threshold threshold — Specifies a threshold for the sampled statistic. A single
interval seconds — Specifies the polling period over which the data is sampled and
3HE 17358 AAAB TQZZA
seconds [rmon-event-type] [startup-alarm alarm-type]
threshold crossing event is generated when the current sampled value is greater than
or equal to this threshold, and the value at the last sampling interval was less than
this threshold. A single threshold crossing event will also be generated if the first
sample taken is greater than or equal to this threshold and the associated startup-
alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be
generated until the sampled value falls below this threshold and reaches less than or
equal the falling-threshold value.
Default
0
Values
–2147483648 to 2147483647
threshold crossing event is generated when the current sampled value is less than
or equal to this threshold, and the value at the last sampling interval was greater than
this threshold. A single threshold crossing event will also be generated if the first
sample taken is less than or equal to this threshold and the associated startup-alarm
is equal to falling or either.
After a rising threshold crossing event is generated, another such event will not be
generated until the sampled value raises above this threshold and reaches greater
than or equal the rising-threshold value.
Values
–2147483648 to 2147483647
Default
0
compared with the rising and falling thresholds.
Values
1 to 2147483647