System Management
hold-time
Syntax
hold-time
Context
config>system>oper-group
Platforms
Only supported on 7210 SAS platforms configured in the access-uplink operating mode
Description
Commands in this context configure hold time information.
group-down
Syntax
[no] group-down time in seconds
Context
config>system>oper-group>hold-time
Platforms
Only supported on 7210 SAS platforms configured in the access-uplink operating mode
Description
This command configures the number of seconds to wait before notifying clients monitoring
this group when its operational status transitions from down to up. A value of zero indicates
that transitions are reported immediately to monitoring clients.
The no form reverts the value to the default.
Default
0
Parameters
time in seconds — Specifies the time, in seconds.
group-up
Syntax
[no] group-up time in seconds
Context
config>system>oper-group>hold-time
Platforms
Only supported on 7210 SAS platforms configured in the access-uplink operating mode
Description
This command configures the number of seconds to wait before notifying clients monitoring
this group when its operational status transitions from up to down.
The no form reverts the value to the default.
Default
4
Parameters
time in seconds — Specifies the time, in seconds.
402
Values
0 to 3600
Values
0 to 3600