Step 5.
Set the protocol to TCP. Network No. and Station No. are not required to be changed (default) because
they are not used.
(For bus connection)
Step 6.
Double-click [GOT] of the PLC side I/F to display [PLC side I/F Detailed Setting of GOT].
Step 7.
Set the IP address and port No. in [Ethernet detail setting for PC and GOT connection].
Set the IP address and port No. to the same as the Ethernet download setting.
➠
22.6.1 (2) Ethernet download setting
Step 8.
Check either of the followings in [Detail setting for GOT and PLC connection].
Bus connection
[via GOT(Bus) transparent mode]
Direct CPU connection
Mark the [via GOT(direct coupled) transparent mode] checkbox.
Step 9.
The screen returns to [Transfer Setup]. Click [Connection Test] to check if MT Works2 has been
connected to the Motion controller (Q mode).
22.7.9
Accessing the servo amplifier by the MR Configurator
Make the FA transparent settings with the of MT Developer.
For details, refer to the following:
➠
22.7.7 Accessing by the MT Developer
22.7.10 Accessing the servo amplifier by the MR Configurator2
Make the FA transparent settings in the MT Works2 communication settings.
For details of MT Works2, refer to the following.
➠
22.7.8 Accessing by the MT Works2