Verifying Services - Huawei SmartAX MA5603T Configuration Manual

Access module
Hide thumbs Also See for SmartAX MA5603T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
----End

13.3.2.7 Verifying Services

This topic describes how to use the PDH/SDH tester to verify the private line access service.
Prerequisites
The private line service has been configured.
Networking
Figure 13-6 Test setup for E1 upstream service
E1 port
loopback
Issue 01 (2014-04-30)
huawei(config-if-tdm-)#display port state 0
---------------------------------------
Port
: 0
State
: normal
Mode
: UDT
Code
: HDB3
Looptype
: -
Timeslot
: -
Clock
: system
CRC4
: -
Signaling
: -
ESF
: -
Impedance
: 120 Ohm
---------------------------------------
3.
Query configurations and the status of the system clock source.
Run the display clock source command to query configurations and the status of the
system clock source.
huawei(config-if-tdm-)#quit
huawei(config)#display clock source
---------------------------------------------------------------
Index
Config
---------------------------------------------------------------
0
YES
1
NO
2
NO
3
NO
4
NO
5
NO
6
NO
7
NO
8
NO
9
NO
---------------------------------------------------------------
ONU
ONU trace
the clock of
the OLT
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
13 FTTO Configuration (Large-sized Enterprise Access)
Type
Source
State
line
0/0/1
Normal
--
-/ -/ -
---
--
-/ -/ -
---
--
-/ -/ -
---
--
-/ -/ -
---
--
-/ -/ -
---
--
-/ -/ -
---
--
-/ -/ -
---
--
-/ -/ -
---
--
-/ -/ -
---
OLT trace
the clock of
the tester
Priority
Output
0
YES
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
OLT
E1 line tester
E1
Internal
free-run
clock
1296