NTP-G318 Connect the ONS 15454 M6 Multishelf Node and the ONS 15454 M6 Subtending Shelves in a Ring Topology
NTP-G318 Connect the ONS 15454 M6 Multishelf Node and the
ONS 15454 M6 Subtending Shelves in a Ring Topology
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Note
The MSM (multishelf management) ports are present on the ECU module. The MSM ports located on the left
side of the ECU module correspond to the TNC/TNCE/TSC/TSCE card in Slot 1, and the MSM ports located
on the right side correspond to the TNC/TNCE/TSC/TSCE card in Slot 8. For more information about the
ECU module and MSM ports, see the
Procedure
Step 1
Using a cross-over (CAT-5) LAN cable:
a) Plug one connector into the MSM port that corresponds to the TNC/TNCE/TSC/TSCE card in Slot 1 of
the ONS 15454 M6 shelf used as the node controller.
b) Plug the other connector into the MSM port that corresponds to the TNC/TNCE/TSC/TSCE card in Slot
1 of the ONS 15454 M6 shelf used as subtending shelf.
Note
Step 2
Using a cross-over (CAT-5) LAN cable:
a) Plug one connector to any one of the remaining MSM ports of the ONS 15454 M6 SSCs in the first layer.
b) Plug the other connector to any one of the MSM ports of the ONS 15454 M6 SSCs in the next layer.
c) Repeat a and b to connect the remaining MSM ports of the ONS 15454 M6 SSCs.
After connecting all the SSCs as per Step 2, connect the last 15454 M6 SSC to the 15454 M6 node
controller to complete the ring.
Note
Cisco ONS 15454 Hardware Installation Guide
430
Use this procedure to connect the ONS 15454 M6 multishelf node and the ONS
15454 M6 subtending shelves in a ring topology.
Cross-over (CAT-5) LAN cables
NTP-G313 Install and Configure the TNC, TNCE, TSC, or TSCE Card. See the
Cisco ONS 15454 DWDM Configuration Guide.
As needed
Onsite
None
External Connection Units, on page
When connecting two shelves using the cross-over cables, it is possible to have shelves not
having controller cards in same slots. Use corresponding MSM ports according to the controller
card slots.
You can connect up to a maximum of 9 SSCs in the ring topology.