Cisco ONS 15454 Hardware Installation Manual page 386

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

DLP-G569 Install the AC Power Module in the ONS 15454 M6 Shelf
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Caution
The node can temporarily work with both 15454-M6-AC and 15454-M6-AC2 power module units installed
on the ONS 15454 M6 shelf. However, during regular operation, the shelf must have either the 15454-M6-AC
or 15454-M6-AC2 power module, but not both.
Tip
Insert the AC power module in Slot A or Slot B, or both (see the following figure).
Note
While inserting the AC power module, apply insertion force only above the hook and not on the air filter (see
the following figure).
Cisco ONS 15454 Hardware Installation Guide
356
#2 Phillips screwdriver
NTP-G252 Install the ONS 15454 M6 Shelf , on page
NTP-G259 Open and Remove the Standard Door of the ONS 15454 M6
Shelf , on page
327.
• Connect the chassis to the office ground. For detailed instructions on how
to ground the chassis, see the
for Cisco CPT and Cisco ONS
Required
Onsite
None
Installing the ONS 15454 M6 Shelf
294.
Electrostatic Discharge and Grounding Guide
Platforms.