DLP-G604 Install the TNC, TNCE, TSC, or TSCE Card
• The red FAIL LED turns on for about 15 seconds.
• All the LEDs including the CRIT, MAJ, MIN, REM, SYNC, and ACO LEDs blink once and turn off
for about 10 seconds.
• ACT/STBY LED blinks for about 1 second.
• All the LEDs including the CRIT, MAJ, MIN, REM, SYNC, and ACO LEDs turn off for about 10
seconds.
• The ACT/STBY, ACO, and PWR LEDs turn on.
• The boot-up process is complete when the PWR LEDs turn green and the amber ACT/STBY remains
on. The ACT/STBY LED turns green if this is the first TNC/TNCE/TSC/TSCE/TNCS-2/TNCS-2O card
installed, and amber if this is the second TNC/TNCE/TSC/TSCE/TNCS-2/TNCS-2O card installed.
Note
Note
Note
Note
The following figure illustrates the installation of TNC and TNCE cards on ONS 15454 M6 shelf.
Figure 172: Installing TNC and TNCE cards on ONS 15454 M6 Shelf
Step 5
Verify that the ACT/STBY LED is green if this is the first powered-up
TNC/TNCE/TSC/TSCE/TNCS-2/TNCS-2O card installed or amber if this is the second powered-up
TNC/TNCE/TSC/TSCE/TNCS-2/TNCS-2O. The IP address, temperature of the node, and time of day appear
on the LCD. The default time and date is 12:00 AM, January 1, 1970.
Step 6
The LCD cycles through the IP address (the default is 192.1.0.2), node name, and software version. Verify
that the correct software version is shown on the LCD. The software text string indicates the node type (SDH
or SONET) and software release. (For example: SDH 09.20-05L-20.10 indicates it is an SDH software load,
Release 9.2. The numbers following the release number do not have any significance.)
Cisco ONS 15454 Hardware Installation Guide
264
It might take up to four minutes for the power alarms to clear.
Alarm LEDs might be on. After completing the TNC/TNCE/TSC/TSCE/TNCS-2/TNCS-2O card
installation, log in to CTC and click the Alarms tab to display the alarms raised on the card. For
procedure to clear the alarm, see the Cisco ONS 15454 DWDM Troubleshooting Guide.
During the TNC/TNCE/TSC/TSCE card initialization, the SFTWDOWN alarm appears twice. The
alarm clears after the TNC/TNCE/TSC/TSCE card boots completely.
If the FAIL LED is on continuously, see the tip in step 8 about the
TNC/TNCE/TSC/TSCE/TNCS-2/TNCS-2O card automatic upload.