Installing the ONS 15454 M12 (ANSI and ETSI) Shelf
Figure 43: Installing the Fan-Tray Assembly on the ONS 15454 ANSI
Step 3
To verify that the tray has plugged into the assembly, look at the fan-tray and listen to determine that the fans
are running.
Step 4
If you want to install an alarm expansion panel on the ONS 15454 ANSI shelf, continue with the
Install the Alarm Expansion Panel (ANSI Only), on page
Alarm, Timing, LAN, and Craft Pin Connections, on page
Stop. You have completed this procedure.

ONS 15454 ANSI Alarm Expansion Panel

The optional ONS 15454 ANSI alarm expansion panel (AEP) can be used with the AIC-I card to provide an
additional 48 dry alarm contacts for the ONS 15454 ANSI: 32 inputs and 16 outputs. The AEP is a printed
circuit board assembly that is installed on the backplane. The following figure shows the AEP board; the left
connector is the input connector and the right connector is the output connector.
The AIC-I without an AEP already contains direct alarm contacts. These direct AIC-I alarm contacts are
routed through the backplane to wire-wrap pins accessible from the back of the shelf. If you install an AEP,
you cannot use the alarm contacts on the wire-wrap pins. For more information about the AIC-I, see the
"Install the Control Cards" chapter in the Cisco ONS 15454 DWDM Configuration Guide.
ONS 15454 ANSI Alarm Expansion Panel
91. Otherwise, continue with the
94.