SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
Parameter
DBA bandwidth
Ethernet Base Station Access Service (in QinQ VLAN Mode)
Parameter
Traffic
classification,
marking, and
scheduling policies
Traffic
monitorin
g and
DBA
policies
14.2.4 Principle of Clock Synchronization Data Plan
Wireless base stations have high requirements on clock precision. Clock synchronization
solutions must be planned based on types and standards of base stations.
Issue 01 (2014-04-30)
Value
l E1 access: Nx8 Mbit/s is
recommended. (N is the
number of E1 lines.)
l T1 access: Nx6 Mbit/s is
recommended. (N is the
number of E1 lines.)
802.1p priority
Queue scheduling
mode
OLT queue ID
(eight queues)
OLT
T-CONT (only for
GPON)
DBA type
DBA bandwidth
Downstream traffic
profile
ONU
Upstream port rate
limit
Downstream port
rate limit
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
14 FTTM Configuration (Base Station Access)
Remarks
-
Value
OAM service of base stations: 7
Synchronization service of base stations: 7
Voice and data services of base stations: 7
PQ
7
QinQ private line services use a separate T-
CONT to distinguish the QinQ private line
services from other services.
Type 3 ("Assured bandwidth+maximum
bandwidth" DBA profile. This type of DBA not
only ensures a fixed bandwidth for users but also
enables users to preempt a certain amount of
bandwidth, but the total bandwidth cannot
exceed the maximum bandwidth.)
Configure DBA bandwidth based on bandwidth
requirements of base stations.
Configure a traffic profile based on bandwidth
requirements of base stations.
Rates of upstream ports are not limited.
Rates of downstream ports are not limited.
1370