Siemens SINUMERIK 840D sl Series Diagnostics Manual page 86

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
Parameters:
%1 = String: MD identifier
Definitions:
A machine data has been set that is locked by an option.
Reactions:
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. For retrofitting the option,
please refer to your machine manufacturer or to a sales representative of SIEMENS AG,
A&D MC.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
8041
Axis %1: MD %2 reset, corresponding option not sufficient
Parameters:
%1 = Axis number
%2 = String: MD identifier
Definitions:
All of the axes selected in the machine data of the assigned option are used. Safety func-
tions have been selected for too many axes in the axial machine data.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy:
--
Program Con-
Switch control OFF - ON.
tinuation:
8044
Option for IPO cycle time %1 ms not set
Parameters:
%1 = Impermissible IPO cycle time
Definitions:
The option for activation of an IPO cycle time of %1 ms has not been set.
Option - Permiss. IPO cycle time:
• Option-free >= 8ms
• 1. 1st step >= 6ms
• 2. 2nd step >= 4ms
• 3. 3rd step >= 2ms
• 4. 4th step <2ms
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
• Buy option
• Increase IPO cycle time (e.g. via MD IPO_SYSCLOCK_TIME_RATIO)
Program Con-
Switch control OFF - ON.
tinuation:
8045
Option for selected cycle settings not set
Definitions:
The option for the 810D Powerline for activation of the same current/speed/position con-
troller/IPO cycle time grid as with the 840D is not set. Without the option, only the set val-
ues of the 810D Standard are permitted.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
2-86
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005