List of Action Numbers
No. 63
Explanation
Activate test run (VDI signal: Rapid traverse override)
Not allowed if
1. Nesting depth too great
2. the active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
− Wait until the preceding ASUB is complete or abort the program.
Remedy
− Abort program
No. 64
Explanation
Deactivate test run (VDI signal: Rapid traverse override)
Not allowed if
1. Nesting depth too great
2. the active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
− Wait until the preceding ASUB is complete or abort the program.
Remedy
− Abort program
No. 65
Explanation
Activate read-in disable for main run block (VDI signal: Read-in disable).
Not allowed if
-
Remedy
-
No. 66
Explanation
Deactivate read-in disable for main run block (VDI signal: Read-in disable).
Not allowed if
-
Remedy
-
No. 67
Explanation
Stop at block end (alarm)
Not allowed if
-
Remedy
-
3-962
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005