Siemens SINUMERIK 840D sl Series Diagnostics Manual page 969

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
No. 100
Explanation
Integrated block search, i.e., a block search is restarted on a stopped program.
Not allowed if
-
Remedy
-
No. 101
Explanation
External zero offset is activated via the PLC. Movement is stopped, a Reorg is per-
formed, the interpreter is switched over and then selected using REPOS and continued
automatically.
Not allowed if
1. The channel is not in AUTO or MDI
2. The channel is stopped and the current block cannot be reorganized.
− Select Auto or MDI
Remedy
− Activate a block change until the NC block can be reorganized.
No. 102
Explanation
Single block type 3 is activated. With single block type 3, a stop is performed at all main
blocks. Unlike single block type 1, the part program command SBLOF is ignored.
Not allowed if
-
Remedy
-
No. 103
Explanation
Stopping of a single axis movement (VDI signal)
Not allowed if
The axis is not controlled by the PLC (exception old reaction with oscillation axis).
Remedy
-
No. 104
Explanation
Stopping of a single axis movement by an alarm
Not allowed if
the axis is not controlled by the PLC. (exception old reaction with oscillation axis).
Remedy
-
© Siemens AG, 2005. All rights reserved